The managed Industrial Ethernet switches of the SCALANCEXP-200product line with 8 or 16 Ethernet ports are optimally suitedforsetting up cabinet-free automation concepts of IndustrialEthernetnetworks with transmission rates of 10/100/1 000 Mbpsin aline, star or ring topology.
Integral redundancy manager for configuration of highavailabilitynetworks in ring topologies
Electric device or network connection西门子PLC模块代理商上海一级代理
Rugged metal enclosure with mounting options on SIMATIC ET200prorack, ITEM rail mounting or direct wall mounting
Rugged device connections with industrial-strength M12plugconnectors, M12 D-coded for FastEthernet (10/100 Mbpsinterfaces),M12 X-coded for Gigabit (1 000 Mbps interfaces),PROFINET andEtherNet/IP-compliant M12 connection technology (M12D-coded, M12X-coded)
Redundant power supply (M12, A-coded)
Console port (M12, D-coded)
Diagnostics on the device by means of prominent LED displaywithintegrated SELECT/SET button (power, link status, datatraffic,display mode)
Integration into the SINEC NMS network management systemforend-to-end network diagnostics with central firmwaremanagement
Error signaling contact with easy adjustment usingSELECT/SETbutton. Configuration storage using the C-PLUG removabledatastorage medium
Grounding screw for external ground connection
Virtual Local Area Network (VLAN) port-based, protocol-basedandIP-based
IGMP snooping und query (use in EtherNet/IP networks)
Access Control List (ACL) MAC-based and IP-based
Link aggregation西门子PLC模块代理商上海一级代理
Standby observer for HRP
IEEE 802.1X (e.g. RADIUS)
Rapid Spanning Tree Protocol/Multi Spanning TreeProtocol(RSTP/MSTP)
Remote Network Monitoring (RMON)
Configuration in the TIA Portal as well as in web-basedmanagement(WBM)
H-Sync for implementation of system redundancy together withaSIMATIC S7-1500R
The XP-200EEC versions are also optimized for use inprocessautomation and feature the following properties:
Conformal coating PCBs
Max. installation altitude 4000 m
Extended temperature range from -40 °C to +70 °C
NAMUR NE 21-compliant
Firmware support for S2 device and CiR/H-CiR
Release and integration capability for SIMATIC PCS 7
Productvariants
For use in PROFINET and EtherNet/IP automation systems,devicevariants are offered that have a corresponding defaultsetting forthe respective automation system. However, the use of adevice witha PROFINET or EtherNet/IP default setting is possible inthe othernetwork at any time by changing the configuration.
Switches with PROFINET delivery state
SCALANCE XP208西门子PLC模块代理商上海一级代理
With eight electrical ports (10/100 Mbps, M12 D-coded) formountingoutside the control cabinet (IP65)SCALANCE XP208EEC
With eight electrical ports (10/100 Mbps, M12 D-coded) formountingoutside the control cabinet (IP65). E with conformalcoatingPCBs for use with increased environmental re, e.g.railapplications (EN 50155/45545)SCALANCE XP208PoE EEC
With four electrical ports (10/100 Mbps, M12 D-coded) andfourelectrical PoE ports (10/100 Mbps M12 D-coded) according toIEEE802.3at type 2 for mounting outside the control cabinet(IP65).E with conformal coating PCBs for use whereincreasedenvironmental re prevail, e.g. rail applications(EN50155/45545)SCALANCE XP216
With twelve electrical ports (10/100 Mbps, M12 D-coded) and4electrical ports (10/100/1 000 Mbps, M12 X-coded) formountingoutside the control cabinet (IP65)SCALANCE XP216EEC
With twelve electrical ports (10/100 Mbps, M12 D-coded) and4electrical ports (10/100/1 000 Mbps, M12 X-coded) formountingoutside the control cabinet (IP65). E with conformalcoatingPCBs for use where increased environmental re prevail,e.g.rail applications (EN 50155/45545)SCALANCE XP216PoE EEC
With eight electrical ports (10/100 Mbps, M12 D-coded),sixelectrical PoE ports (10/100 Mbps, M12 D-coded) according toIEEE802.3at type 2, and two electrical PoE ports(10/100/1 000Mbps, M12 X-coded) according to IEEE 802.3at type2. The switch canalso be operated with only two PoE ports (10/100Mbps, M12 D-coded)according to IEEE 802.3at type 2 and two PoEports(10/100/1 000 Mbps, M12 X-coded) according to IEEE802.3attype 2. The switch is designed for mounting outside thecontrolcabinet (IP65), and is e with conformal coating PCBs forusewhere increased environmental re prevail, e.g. railapplications(EN 50155/45545)Switches with EtherNet/IP delivery state
Benefits西门子PLC模块代理商上海一级代理
Ideal solution for configuring Industrial Ethernet line, starandring topologies
Industrial-grade plug-in connection (10/100 Mbps M12,D-codedand 10/100/1 000 Mbps, X-coded)
High network availability through configuration of redundantringtopologies (redundancy manager integrated)
Integration of SCALANCE XP-200 Industrial Ethernet switchesinexisting network management systems (e.g. SINEC NMS) throughSNMPaccess
Easy integration in the process diagnostics and systemdiagnosticswith PROFINET and EtherNet/IP
Integrated configuration and diagnostics in STEP 7/TIAPortalbring significant advantages during the engineering,commissioning,and operating phases of a plant
C-plug enables fast device replacement in the event of anerror
Integration of switches in systems with simple S2 systemredundancyand Configuration in Run (CiR/HCiR)
Since Configuration in Run (CiR/H-CiR) issupported,PROFINET-defined configuration changes to the switch areperformedduring operation
Easy integration in the process and system diagnostics withPROFINETvia SIMATIC PCS 7
Application
The SCALANCE XP-200 Industrial Ethernet switchesenablecost-effective configuration of Industrial Ethernet line,star orring topologies with switching functionality for networks inwhichhigh availability or remote diagnostic capabilitiesarerequired.
Features:西门子PLC模块代理商上海一级代理
Industry-compatible thanks to rugged metal housing (e.g. for useinrail applications with increased mechanical loads)
Use outside the control cabinet also possible (IP65 degreeofprotection)
Various mounting options (SIMATIC ET 200pro rack, ITEMrailmounting, wall mounting)
Versatile diagnostic and management capabilities: e.g.signalingcontact, remote access via SNMP, web-based managementandintegrated diagnostics with PROFINET and EtherNet/IP
Use in rail applications thanks to EN 50155 and EN 45545approvaland conformal coating PCBs
Use in harsh ambient conditions (-40 °C to +70 °C)
Installation altitudes up to 4 000 m
Firmware support of: S2 device and CiR/H-CiR. The devicesarereleased for SIMATIC PCS 7 and are integration-capable
Design西门子PLC模块代理商上海一级代理
The SCALANCE XP-200 Industrial Ethernet switches with ruggedmetalenclosure are optimized for use outside the controlcabinet.Mounting options on ET 200pro rack, ITEM rail mounting ordirectwall mounting in variety of mounting positions.
The switches with IP65 degree of protection feature:
Two 4-pole M12 connections (A-coded) for connection ofredundantsupply voltage (2 x 24 V DC)
An LED display for display of status information usingSELECT/SETbutton (power, link status, data traffic, power supply,signalingcontact)
One 2-pole M12 interface (B-coded) for connecting thefloatingsignaling contact
One 2-pole M12 interface (D-coded) as console access
The SCALANCE XP-200 switches are available with the followingporttypes:
10/100 Mbps, M12 connection(D-coded);
automatic detection of the data rate (10 or 100 Mbps),withautosensing and autocrossover function for connection of IEFCcables via IE FC M12 plug PRO 2x2 up to 100 m.10/100/10 000 Mbps, M12 connection(X-coded);
automatic detection of the data rate (10 or 100or1 000 Mbps), with autosensing and autocrossoverfunctionfor connection of IE FC cables via IE FC M12 plug PRO 4x2up to100 m.
Function西门子PLC模块代理商上海一级代理
Configuration of electrical Industrial Ethernet line, star andringtopologies
Fast redundancy in the ring with:
High Speed Redundancy Protocol (HRP); up to 0.3 secondsforreconfiguration of the ring with 50 switches in thering
PROFINET MRP (Media Redundancy Protocol); up to 0.2 secondsforreconfiguration of the ring with 50 switches in thering
The functioning of the ring is continuously monitored bytheintegrated redundancy manager. It recognizes failure ofatransmission link in the ring or failure of a SCALANCE XP-200andactivates the substitute path within 0.3 seconds with HRPor0.2 seconds with MRP
Use in ring topologies together with SCALANCE X-200, X-300,XM-400and XR-500
Redundant connection of rings via HRP standbymaster/slavefunction
Uncrossed connecting cables can be used due toautocrossoverfunction integrated in the ports
Easy diagnostics using signaling contact, SNMP and webbrowser
Easy copper cable diagnostics via web browser for localizingcablebreaks
Incorporation in the integrated system diagnostics of the TIAPortalwith PROFINET diagnostics of data traffic using aconfigurablemirror port and a commercially available networkanalyzer (e.g. viaBUSANALYZER AGENT XM-400)
Optimized support of PROFINET real-time communication (RT)throughprioritizing
Fast device replacement in the event of a fault by usingtheoptional C-plug removable data storage medium (not includedinscope of delivery)
Networktopology and network configuration西门子PLC模块代理商上海一级代理
The SCALANCE XP-200 Industrial Ethernet switches in IP65 degreeofprotection are typically mounted outside the control cabinet.Theycan be installed in line, star and ring electricalsystemtopologies.
When configuring the network, the following boundary conditionsmustbe observed:
Length of the twisted pair line between two SCALANCE XIndustrialEthernet switches:
Max. 100 m with IE FC cableandIE FC M12 plug PRO
IP address:西门子PLC模块代理商上海一级代理
The IP address is assigned via the DHCP (Dynamic HostConfigurationProtocol). If there is no corresponding server in thenetwork, theIP address can be assigned using the supplied softwaretool PST(Primary Setup Tool) or STEP 7/TIA Portal.
SCALANCE XP208 and SCALANCE XP216 in factory automation