西门子模块代理商|海南PLC模块代理商
西门子模块代理商|海南PLC模块代理商
西门子模块代理商|海南PLC模块代理商
SONOKITflowmeter (with FUS060 or FUS080) |
概述
SONOKIT is a transit time based ultrasonic flowmeter forretrofitting on existing pipelines.
The kit offers all necessary parts and special tools to make theinstallation as 1-path or 2-path flowmeter.
The set is made for installation on empty pipes or pipes underpressure without process shut-down (hot-tap).
Please contact Siemens for further information on hot-tap tools andinstructions.
SONOKIT has in-line transducers (in contact with media) whichassure superior accuracy and performance.
优势
Cost-effective solution – contains all the necessary components forretrofitting
SONOKIT is easy to install in pipeline sizesDN 200 to DN 3000 (8” to 120”) 1-pathDN 100 to DN 2400 (4” to 96”)
No bypass installation necessary – withstands pressures up to40 bar (580 psi) and media temperatures between‑20 °C and +200 °C (‑4 °F and +392 °F)
High accuracy – the bigger the pipe, the more accurate theresult
Solid construction and no moving parts for a 100 % maintenanceand obstruction-free flowmeter
The SONOKIT comes with transducers in IP68 enclosure
Available in a robust version that can be buried and withstandsconstant flooding
In-line transducers assure superior accuracy and performance
Automatic calculation of the calibration factor when pipe geometrydata are entered in the transmitter
FST030 transmitter, modified for inline, HART or Modbus
FUS080 transmitter, battery or mains-powered
应用
Raw water intake for water treatment plants
Water distribution systems
Irrigation systems
Power generation (energy and water)
District heating plants
Cooling water plants within the industry and in power stations
Systems within the oil and refinery business
Sewage treatment plants
Plants transporting non-conductive liquids
设计
The SONOKIT package box contains all necessary parts to build anultrasonic flowmeter on existing pipes depending on choices atordering:
Papers to wrap around pipes for alignment of sensors
Transducer alignment tools
Mounting plates, transducer holders and SONO 3200transducers
Transducer cables
SITRANS FUS060 or FUS080 transmitter for wall mounting
For pipes bigger DN 500 (20") please order FST030 Transmitterseperately (FDK-085X6329)
技术规范
The transmitter related to this system is the SITRANS FUS080 orFST030. See Technical specifications for FUS060 and FUS080.
Accuracy | |
Typical,depending on accuracy of measurements of installation | 2-path:≤ ± (0.5 … 1.5 %) |
1-path:≤ ± (1 … 3 %) | |
Note: |