Triaxial MEMS DC accelerometer, 200 mV/g, +/- 10 g, +6 to 30 VDCexcitation
Sensitivity: (±3%) 200 mV/g(20.4 mV/(m/s²))
Measurement Range: ±10 g pk(±98.1 m/s² pk)
Electrical Connector: 9-Pin
Weight: 0.8 oz(22.7 gm)
Model: 3713E11200GTriaxial MEMS DC accelerometer, 10 mV/g, +/-200 g, +6 to 30 VDCexcitation
Sensitivity: (±3%) 10 mV/g(1 mV/(m/s²))
Measurement Range: ±200 g pk(±1962.0 m/s² pk)
Model: 3713E1125GTriaxial MEMS DC accelerometer, 80 mV/g, +/-25 g, +6 to 30 VDCexcitation
Sensitivity: (±3%) 80 mV/g(8.15 mV/(m/s²))
Measurement Range: ±25 g pk(±245.2 m/s² pk)
Model: 3713E112GTriaxial MEMS DC accelerometer, 1000 mV/g, +/-2 g, +6 to 30 VDCexcitation
Sensitivity: (±3%) 1000 mV/g(101.9 mV/(m/s²))
Measurement Range: ±2 g pk(±19.6 m/s² pk)
English:SI: PERFORMANCESensitivity (±3 %)40 mV/g4.1mV/(m/s²)[2] Measurement Range±50 g pk±490.5 m/s² pkFrequency Range (±3 dB)0 to 2000 Hz0 to 2000 Hz[1] FrequencyRange (±3 dB)0 to 1000 Hz0 to 1000 Hz[4] Phase Response (100Hz)<10 °<10 °
Non-Linearity≤1 %≤1 %[3] Broadband Resolution (0.5 to 100Hz)1.0 mg rms0.010 m/s² rms[1] Transverse Sensitivity≤5 %≤5%
ENVIRONMENTALOverload Limit (Shock)±5000 g pk±49050 m/s² pk
Temperature Range (Operating)-65 to +250 °F-54.0 to +121 °C
Temperature Range (Storage)-65 to +250 °F-54.0 to +121 °C
Temperature Coefficient of Sensitivity±3 %±3 %[6] Zero gOffset Temperature Coefficient±2 % FSO±2 % FSO[5][6] BaseStrain Sensitivity (Measured at 250 µε).001 g/µε.01(m/s²)/µε[1] Magnetic Sensitivity100 µg/gauss9.8(m/s²)/Tesla[1] ELECTRICALExcitation Voltage6 to 30 VDC6 to 30VDC
Current Consumption≤30 mA≤30 mA
Output Impedance≤120 Ohm≤120 Ohm
Offset Voltage±80 mVDC±80 mVDC[7] Spectral Noise (1 to 100Hz)200 µg/√Hz1962 (µm/sec2)/√Hz[1] ElectricalIsolation (Case)>100000000 Ohm>100000000 Ohm
PHYSICALHousing MaterialTitaniumTitanium
SealingHermeticHermetic
Size - Length0.85 in21.6 mm
Size - Width0.85 in21.6 mm
Size - Height0.85 in21.6 mm
Weight0.8 oz22.7 gm
Electrical Connector9-Pin9-Pin
Electrical Connection PositionSideSide
Mounting Thread10-32 Female10-32 Female
All specifications are at room temperature unless otherwisespecified.
Product Notes
[1] Typical.
[2] Measured at 100 Hz.
[3] Least-squares, straight line method, % FSO.
[4] Minimum, verified with Calibration data.
[5] FSO = Full Scale Output over the Measurement Range (4VDC).
[6] -65 to +250 °F, ref. 75 °F (-54 to +121 °C, ref. 24 °C)
[7] Offset tolerance is based on 10 ft of 037 test cable.
[8] See PCB Declaration of Conformance PS027 for details.
Accessories:
Supplied080A12Adhesive Mounting Base(1)081B05Mounting Stud (10-32 to 10-32)(1)
ACS-145TTriaxial Calibration Phase and Magnitude from 2 Hz to ±3dBusing Linear scale(1)
M081B05Mounting Stud 10-32 to M6 X 0.75(1)