西门子S7-1200CPU模块代理
Line voltage |
| SINAMICS G115D distributed converters | ||||
---|---|---|---|---|---|---|
6SL352 . - | . X . . 2-2A . 0 | . X . . 3-0A . 0 | . X . . 4-0A . 0 | . X . . 5-** . 0 | . X . . 7-** . 0 | |
Rated outputcurrent IN1) | A | 5.9 | 7.7 | 10.2 | 13.2 | 19 |
Maximumoutput current Imax | 11.8 | 15.4 | 20.4 | 26.4 | 38 | |
Ratedpower | kW | 2.2 | 3 | 4 | 5.5 | 7.5 |
Rated pulsefrequency | kHz | |||||
Efficiency η According toIEC 61800-9-2 | 96.87 | 96.85 | 96.74 | 97.68 | 97.69 | |
Powerloss 2) At ratedoutput current | 0.096 | 0.126 | 0.173 | 0.171 | 0.246 | |
Internalbraking resistor | ||||||
Continuousbraking power PDB | W | 10 | 20 | |||
Peakpower Pmax | 100 | 200 | ||||
Rated inputcurrent 3) | 5.18 | 6.76 | 8.95 | 11.88 | 17.11 | |
Line supplyconnection | ||||||
Conductorcross-section | mm2 | 2.5 ... 6 | 4 ... 6 | |||
PEconnection (externalconnection) | ||||||
Conductorcross-section (recommended) | ||||||
Motorconnection | ||||||
U2, V2, W2,PE | 2.5 ... 4 | 4 | ||||
Motorbrake | 0.75 ... 4 | |||||
Temperaturesensor | 0.75 ... 1.5 | |||||
Degree ofprotection | IP65/IP66/ULtype 4X | IP65/IP66/ULtype 4X | ||||
Framesize | FSB | FSB | FSC | |||
Dimensions | ||||||
Width | mm (in) | 425(16.73) | ||||
Height 4) | 180(7.09) | |||||
Depth | 134(5.28) | 169(6.65) | ||||
Weight,approx. The exactweights can be found in the data sheet resulting from theconfiguration on the Siemens Product Configurator. | kg (lb) | 8.4(18.52) | 8.8(19.40) | 9.1(20.07) |
1) The rated output current IN is based on the dutycycle for high overload (HO).
2) Typical values. More information can be found on theinternet a./cs/document/94059311.
3) The input current depends on the motor load and lineimpedance. The input currents apply for load at rated power for aline impedance corresponding to uK = 4 %.
4) The data for the height applies regardless of theconnection. Depending on connection type, the additional heightamounts to:
- For version with cable gland: 30 mm (1.18 in)
- For version with cable gland and motor connection Q8/0: 42 mm(1.65 in)
- For version with plug-in connection: 47.5 mm (1.87 in)
- For version with 24 V DC power supply: 60 mm (2.36 in)
The version with cable gland does not have a cable gland in itsdelivery state. The dimensions with cable gland apply to theconverter with cable gland e with the optional installationkit for SINAMICS G115D wall-mounted.
特性曲线
SINAMICS G115D, internal braking resistor, relative duty cyclein relation to a cycle of 120 s
Derating dataPulse frequency
Rated power at 400 V 3 AC | Rated output current in A for a pulse frequency of | |||||||
---|---|---|---|---|---|---|---|---|
kW | hp | 4 kHz | 6 kHz | 8 kHz | 10 kHz | 12 kHz | 14 kHz | 16 kHz |
0.37 | 0.5 | 1.3 | 1.11 | 0.91 | 0.78 | 0.65 | 0.59 | 0.52 |
0.55 | 0.75 | 1.7 | 1.45 | 1.19 | 1.02 | 0.85 | 0.77 | 0.68 |
0.75 | 1 | 1.87 | 1.54 | 1.32 | 1.1 | 0.99 | 0.88 | |
1.1 | 1.5 | 3.1 | 2.64 | 2.17 | 1.86 | 1.55 | 1.4 | 1.24 |
1.5 | 2 | 4.1 | 3.49 | 2.87 | 2.46 | 2.05 | 1.85 | 1.64 |
2.2 | 5.02 | 4.13 | 3.54 | 2.95 | 2.66 | 2.36 | ||
3 | 6.55 | 5.39 | 4.62 | 3.85 | 3.47 | 3.08 | ||
4 | 5 | 8.67 | 7.14 | 6.12 | 5.1 | 4.59 | 4.08 | |
5.5 | 11.22 | 9.24 | 7.92 | 6.6 | 5.94 | 5.28 | ||
7.5 | 16.15 | 13.3 | 11.4 | 9.5 | 8.55 | 7.6 |
Ambient temperature
Permissible output current as a function of the ambienttemperature
Installation altitude
Permissible output current as a function of the installationaltitude
No derating necessary at the permissible input voltage depending onthe installation altitude.
尺寸图
SINAMICS G115D, frame size FSA, without fan
SINAMICS G115D frame size FSB, without fan, rated power2.2 kW and 3 kW
SINAMICS G115D, frame size FSB, with fan, rated power 4 kW
SINAMICS G115D frame size FSC, with fan
The data for the height applies regardless of the connection.Depending on connection type, the additional height amounts to:
For version with cable gland:30 mm (1.18 inches).
For version with cable gland and motor connection Q8/0:42 mm (1.65 inches).
For version with plug-in connection:47.5 mm (1.87 inches).
For version with 24 V DC power supply:60 mm (2.36 inches).
The version with cable gland does not have a cable gland in itsdelivery state. The dimensions with cable gland apply to theconverter with cable gland e with the optional installationkit for SINAMICS G115D wall-mounted.
Mounted with 4 M5 bolts, 4 M5 nuts, 4 M5 washers.
Ventilation clearance required (for wall mounting) on theconnection side of the converter:200 mm (7.9 inches).
Ventilation clearance required (for wall mounting) on thenon-connection side of the converter:150 mm (5.9 inches).
All dimensions in mm (values in brackets are in inches).