西门子S7-1200继电器模块CPU1211C
西门子S7-1200CPU模块
The SINAMICS G115D distributed drive system provides fullypreconfigured and ready-to-connect solutions in a modular conceptthat includes the converter, motor and gearbox.
The converter supports SIMOGEAR 2KJ8 geared motors with three-phaseasynchronous motors with efficiency class IE3 or high-efficiencysynchronous reluctance motors with efficiency class IE4.
It meets all re for horizontal conveyor systemapplications – from simple speed control to sophisticatedencoderless vector control. Integrated functions such as fast/slowspeed switchover, Quick Stop and limit position disconnector makethe SINAMICS G115D particularly suitable for applications inconveyor systems.
For applications that require safety technology, theSINAMICS G115D offers the integrated STO (Safe Torque Off)function, which can be implemented without additional externalcomponents.
The SINAMICS G115D distributed drive system is availablewall-mounted and motor-mounted.
Example: SINAMICS G115D distributed drive system,wall-mounted, PROFINET, version with plug-in connection, FSA,1.5 kW
The wall-mounted converter with its different versions (framesizes FSA to FSC) in a performance range from 0.37 kW to7.5 kW is suitable for a large number of differentapplications. Thanks to the compact design with degree ofprotection IP65 (plug-in connection) or IP66 (cable gland), it canbe seamlessly integrated into the system.
SINAMICS G115D distributed drive system, motor-mountedExample: SINAMICS G115D distributed drive system,motor-mounted, PROFINET, version with cable gland, FSA,1.5 kW, SIMOGEAR motor LE 90, gearbox B49, hollowshaft
Example: SINAMICS G115D distributed drive system,motor-mounted, PROFINET, version with plug-in connection, FSA,1.5 kW, SIMOGEAR motor LE 90, gearbox B49, hollowshaft
The motor-mounted converter with its different versions (framesizes FSA and FSB) in a performance range from 0.37 kW to4 kW is suitable for a large number of different applications.Thanks to its compact design with degree of protection up to IP65,it can be seamlessly integrated into the system.
Perfect combination with SIMATIC controllers and PROFINETIntegration via PROFINET communication with PROFIsafe,AS-Interface, EtherNet/IP into a higher-level control system isvery easy thanks to full TIA Portal integration, which provides atool as well as an operating and data management concept. Inaddition, an optional web server module is available with the webserver module SINAMICS G120 Smart Access (SAM) – a WLAN-basedweb server solution for simple and fast wireless setup withsmartphones, tablets, or laptops during commissioning and fordiagnostics.
The SINAMICS G115D distributed drive system is ready fordigitalization. All operating data can be transferred to theMindSphere cloud solution. The MindSphere application "AnalyzeMyDrives" facilitates the process evaluation of operating data,with the possibility of adaptation to individual customerre. This simplifies the recording and evaluation of theoperating conditions of the drive system.
Reasons for using the SINAMICS G115D distributed drive systemUser-friendly modular solution – pre-configured and ready forconnection
Versatile, robust and reliable system
New design for quick and easy installation, cabling andcommissioning
The wall-mounted and motor-mounted variants use the sameplatform
No control cabinet required, thanks to the installation on themachine less space required and lower cooling re
Long cables between the converters and the motors can be avoided(thus less power loss, reduced interference emissions, and lowercosts for shielded cables and additional filters)
Supports SIMOGEAR 2KJ8 geared motors with asynchronous motorsand high-efficiency synchronous reluctance motors according toefficiency class IE4
Worldwide use of the SIMOGEAR 2KJ8 geared motors independent ofthe line voltage
Temperature range from -30 °C to 55 °C (suitable forinstallation in deep-freeze applications)
Integrated safety, STO (Safe Torque Off) via fail-safe digitalinput F-DI or PROFIsafe
Perfectly prepared for digitalization thanks to variouscommunication interfaces and integration of the AMD (AnalyzeMyDrives) application into the cloud solution MindSphere
Special properties for the intralogistics market (e.g. repairswitches, local remote control, Safety Integrated, conveyortechnology functions)
Siemens offers an innovative portfolio of frequency convertersfor optimal implementation in distributed drive solutions. Thestrengths of the individual members of the converter family alloweasy adaptation to the most diverse application re:
Identical connection systems
User-friendly commissioning and configuration tools
Products from the family of distributed drives:
SINAMICS G115D distributed drive system (wall andmotor-mounted)
SINAMICS G120D frequency converters
SIMATIC ET 200pro FC-2 frequency converters
SIRIUS M200D motor starters
The SINAMICS G115D distributed drive system is available asa wall-mounted and motor-mounted version, with degree of protectionIP65/66.
The performance range for the wall-mounted version, for ranges from0.37 kW to 7.5 kW and in the motor-mounted version, forranges from 0.37 kW to 4 kW.
The converter is configurable regarding fieldbus communication(without, AS-Interface or PROFINET / EtherNet/IP) and connectionmethod (cable gland or plug-in connection). Furthermore, thewall-mounted version can be configured with a repair switch, localremote control and the control voltage of the motor holdingbrake.
State-of-the-art IGBT technology with pulse width modulation(PWM) is used for extremely reliable and flexible motor operation.The closed-loop control electronics control and monitor the powerelectronics and the connected motor in several different controlmodes that can be selected.
The sensors of the conveyor element can be connected to thedigital inputs of the converter. These signals can be transmittedto the higher-level control for further processing via PROFINET,EtherNet/IP or AS-Interface.
Safety IntegratedThe SINAMICS G115D distributed drive systems are alreadye with the Safety Integrated Function STO (Safe Torque Off),with certification according to IEC 61508 SIL 2 as wellas EN ISO 13849-1 PL d and Category 3. This canbe activated either via the PROFIsafe communication protocol or viathe fail-safe digital input F-DI.
Siemens Product ConfiguratorThe Siemens Product Configurator helps you configure the optimumdrive technology products for a number of applications – startingwith gearboxes, motors, converters as well as the associatedoptions and components and ending with controllers, softwarelicenses and connection systems.
The Siemens Product Configurator can be used on the internetwithout re any installation. The Siemens ProductConfigurator can be found in the Siemens Industry Mall at thefollowing address:
www./spc
SINAMICS Startdrive is a tool integrated into the TIA Portal forconfiguring, commissioning and diagnostics of the SINAMICSconverter family. SINAMICS Startdrive (V16 update 4 and higher) canbe used to implement converter tasks with most of theSINAMICS G and SINAMICS S converter series. Thecommissioning tool has been optimized in terms of simplicity, easeof use, and consistent use of the benefits of the TIA Portal toprovide a uniform working environment for PLC, HMI and drives.
The SINAMICS Startdrive Basic commissioning tool is availablefor free on the internet at
www./startdrive
The SINAMICS G115D distributed drive system is easilyconfigured with the TIA Selection Tool under the drive dimensioningplug-in. It provides support when selecting the hardware andfirmware components necessary to implement a drive task. Theplug-in encompasses the configuration of the entire drive systemand allows the handling of individual drives.
Intuitive user interface, menu-based operation and help
Configuration of the SINAMICS G115D distributed drivesystem
Adjustable load cycles and various mechanical systemsintegrated
Interface to the TIA Portal and Industry Mall
The TIA Selection Tool is available for free on the internetat
www./tia-selection-tool-standalone
Electrical planning: Even easier with software!
Electrical planning for power distribution in non-residentialand industrial buildings has never been more complex. To ensureyou, as a specialist planner, have the best hand when it comes toelectrical planning with SINAMICS drives, we provide support withthe following efficient software tools:
SIMARIS design for dimensioning
SIMARIS project for calculating the space re of thedistribution boards
For SINAMICS G115D, Siemens offers an optional extension ofwarranty up to 2½ years via Service Protect:
Free for the first 6 months after registering the productat:
//myregistration.
With costs for 1 or 2 additional years for wall-mounted andmotor-mounted versions
(complete system with converter and geared motor)
More information is available at:<br. cs="" ww="" en="" sc=""4842
Concerning standard warranty please ask your partner at Siemens.Your partner can be found in our Personal Contacts Database at:
www./automation-contact
Compact Operating Instructions are supplied in hard copyform in German, English and Chinese with everySINAMICS G115D.
To select the helical geared motor, parallel shaft geared motor,bevel geared motor and helical worm geared motor, see "Gearboxselection" or "Dimensional drawings" in the Industry Mallat:
www./sinamics-g115d/gear-selection-wall-mounted
or
www./sinamics-g115d/gear-selection-motor-mounted
The latest technical documentation (catalogs, dimensionaldrawings, certificates, manuals and operating instructions) as wellas further technical specifications are available on the internetat:
www./sinamics-g115d/documentation
and in the Siemens Product Configurator
www./sinamics-g115d/configuration
SINAMICS G115D distributed converters, wall-mounted ·380 ... 480 V 3 AC
Rated power 1)
Rated output current IN2)
Rated input current 3)
Frame size
SINAMICS G115D, wall-mounted
Degree of protection IP65/IP66/UL type 4X
with integrated line filter class A according toEN 55011
400 V
480 V
at 400 V
Data position in Article No.
kW
hp
A
123456
7
-
8
9
10
11
12
13
14
15
16
380 ... 480 V 3 AC · Rated pulsefrequency 4 kHz · Input fre ... 66 Hz
0.37
0.5
1.3
1.23
FSA
6SL352
❑
-
X
0
3
A
0.55
0.75
1.7
1.58
5
0.75
1
2.2
1.99
7
1.1
1.5
3.1
2.69
1.5
2
4.1
3.48
2.2
5.9
5.18
FSB
3
4
7.7
6.76
4
10.2
8.95
5.5
7.5
13.2
11.88
FSC
7.5
10
19
17.11
Article No. supplements
Brake control
180 V DC (independent of the line voltage) *)
380 ... 480 V AC (such as line voltage)
Operating options
Without operating option *)
Repair switch
Local remote control
Repair switch and local remote control
Connection type
Fieldbus communication
I/O
Motor
380 ... 480 V AC
24 V DC
Cable gland with daisy chain
without
Cable gland *)
Cable gland
Power supply integrated
H
M12
M12
Cable gland
6
Q8/0
Cable gland
R
Cable gland
2 × Power M12 6)
M12
Cable gland
Plug-in connection without daisy chain
M12
Q8/0
Q4/2
7/8" 4)
B
Q4/2
Power M12 6)
5)
Power M12 4)
C
MQ15 5)
D
K
L
M
Plug-in connection with daisy chain
M12
Q8/0
2 × Q4/2
2 × 7/8" *) 4)
E
2 × Power M12 6)
Power supply integrated
N
Fieldbus communication
AS-Interface 7)
Without fieldbus communication
PROFINET, EtherNet/IP 7)
F
*) If "brake voltage 180 V DC" and "withoutoperating option" are selected in conjunction with one of theconnection types A0, A2 or E0, the deliverytime changes from "standard delivery time" to "delivery exstock".
1) Rated power based on the rated output current IN.The rated output current IN is based on the duty cyclefor high overload (HO).
2) The rated output current IN is based on theduty cycle for high overload (HO). These current values are validfor 400 V or 480 V and are specified on the rating plateof the converter.
3) The input current depends on the motor load and lineimpedance. The input currents apply for load at rated power for aline impedance corresponding to uK = 4 %. Thecurrent values are specified on the rating plate of theconverter.
4) Plug-in connectors not available with fieldbuscommunication AS-Interface.
5) Not suitable for UL applications (FSA and FSB). Notavailable for FSC.
6) Version cannot be ordered with fieldbus communicationAS-Interface.
7) The connection types A0 and H0 arenot possible for fieldbus communication (AS-Interface, PROFINET orEtherNet/IP).
SIMOGEAR geared motors for/with SINAMICS G115Dwall-mounted/motor-mounted - Structure of the Article No.